Worker does not appear
- Start the Manager first.
- Verify the IP and TCP 32761.
- Allow UDP 32762 for discovery.
- Restart after settings changes.
- Run only one Worker instance.
Configure a Manager, connect a Worker, submit from Blender or After Effects, and monitor the render from any browser on your local network.
Coordinates jobs, assigns tasks, and hosts the web interface.
Runs Blender and/or aerender to produce frames.
Submits jobs and monitors them in a browser.
A DCC add-on writes a small work-order file and a temporary project copy to shared storage. The Manager detects the work order, divides it into tasks, and assigns them to compatible Workers. Workers read shared projects and assets, write render output, and report progress. Any computer on the LAN can open the Manager's web interface.
\\FILESERVER\Flagship ├── Work Orders ├── Temporary Projects └── Temporary Output
Prefer UNC paths over mapped drive letters. A mapped drive such as L: might not exist for another user, an elevated process, or a process launched at startup.
| Flagship setting | Example path | Required access |
|---|---|---|
| Work Orders | \\FILESERVER\Flagship\Work Orders | Manager and submitting workstations: read/write. Workers also need access for After Effects previews. |
| Temporary Projects | \\FILESERVER\Flagship\Temporary Projects | Manager, Workers, and submitting workstations: read/write. |
| Blender Temporary Output | \\FILESERVER\Flagship\Temporary Output | Blender Workers and submitting Blender workstations: read/write. |
| Protocol and port | Purpose |
|---|---|
| TCP 8008 | Manager web interface |
| TCP 32761 | Manager-to-Worker communication |
| UDP 32762 | Automatic Manager discovery |
If UDP discovery cannot cross a VLAN or VPN, configure the Manager IP manually in Worker Settings. TCP 32761 must still be reachable.
Flagship_Manager.exe. On the activation page that opens, enter the promo code supplied by MutinyFX and select Start 30-day trial. Activate on the Manager computer while it has internet access.Configure Flagship Firewall.cmd from the release package or deploy TCP 8008, TCP 32761, and UDP 32762 for the Manager.\\FILESERVER\Flagship\Work Orders\\FILESERVER\Flagship\Temporary Projects\\FILESERVER\Flagship\Temporary OutputFrom Computer 3, open http://MANAGER-IP:8008, for example http://192.168.1.25:8008.
Flagship_Manager.exe is running.ipconfig on Computer 1 to confirm its IPv4 address.Flagship Worker Settings.exe.RENDER-02.aerender.exe and blender.exe. The current Settings utility expects both to be valid. Fusion is optional future support.32761.FlagshipWorker.exe.Worker settings are stored at C:\Users\Public\Documents\Flagship_Worker_Config.txt. Restart the Worker after changing them.
The current file is Blender Flagship Output Panel v2_2.py and declares Blender 5.0 or later.
Blender Flagship Output Panel v2_2.py and enable Flagship Output Panel if needed.\\FILESERVER\Flagship.Enter the root, not a child folder. The add-on automatically appends Work Orders, Temporary Projects, and Temporary Output; these must match the Manager paths.
AE Flagship UI Panel 1.3.3.jsx, then restart After Effects.\\FILESERVER\Flagship\Work Orders\\FILESERVER\Flagship\Temporary ProjectsSettings are saved for the current user as Flagship_Renderer_AEPanel_Settings.txt in Documents.
The optional Flagship_AE_Render_Settings.json and [Flagship Render Output Modules].aep support project settings and previews. A normal Flagship Render can proceed without valid preview settings after confirmation; Flagship Render w/ Previews requires them.
Start with a small, low-resolution test of a few frames, with every asset on shared storage.
Temporary Output.∞ or 0 to let the Manager calculate the split.http://MANAGER-IP:8008.http://MANAGER-IP:8008.localhost, remotely.Stop the Manager and back up C:\Users\Public\Documents\Flagship_Settings.txt before editing it. The three values must continue to match the add-ons' shared layout.
Repeat the Worker setup on every additional render computer. Give each Worker a unique name, use the same Manager IP and TCP port 32761, and verify that its renderer versions and access to project dependencies match the jobs it will accept.